LEVEL II
Materials
Procedure
b. Place exactly 15 ml.9 of 40% sucrose in the right chamber and 15 ml. of 10% sucrose in the left chamber of the gradient device.
c. Open the flow from the right chamber to the centrifuge tube. Be sure there is a tube in place, that the flow is directed down the inside of the tube and that the magnetic stirrer is functioning.
d. Immediately open the valve on the left chamber and insure that sucrose is flowing from left to right, thereby diluting the 40% sucrose with 10% sucrose.
e. Allow the flow to continue until all of the sucrose enters the centrifuge tube.
b. Have a series of 30-35 test tubes ready to accept the effluent from the tubes. Each tube should be labeled and kept in order.
c. Push down on the centrifuge tube (Gently!) in order to puncture the bottom of the tube and immediately begin to collect the effluent.
d. Count the drops that fall from the device, and place 40 drops into each tube.