Biosynthetic labeling
How long should cells be labeled?
The ideal length of time to label cells depends on the protein
of interest and the label that you are using. If you want to
label an unstable protein with 35S-methionine, a short labeling
interval--no more than 2 hr--is best. If you are studying a stable
protein, a longer label may be preferable. The issue is the half-life
of the protein of interest relative to the half-life of the background
bands. The half-life of total cellular protein is 45 to 50 hr.
Labeling with 32Pi is different.
In most cases, the phosphate in proteins undergoes continual
turn-over. Therefore, both old and newly-synthesized proteins
become labeled soon after 32Pi is added to the cells. A short
labeling period with 32Pi is advantageous in that the labeling
of RNA and DNA is less obvious than in cells labeled over-night.
Additionally, for those of you studying tyrosine protein kinases,
phosphotyrosines tend to turn-over faster than the bulk of either
phosphoserine or phosphothreonine and thus are preferentially
labeled during brief labeling.
If, however, you want to look at the steady-state abundance of
phosphate in proteins, lipids, or RNA, an over-night labeling
period may be the best. Under these conditions, you can be reasonably
certain that the specific activity of the ATP pool in the cell
and of the phosphates in macromolecules is beginning to approach
that of the medium. Additionally, the amount of label present
in proteins, lipids and RNA should now reflect the amount of
phosphate present, rather than the rate of turn-over of the phosphate.
An issue to consider however is the fact that radiation damage
can induce the stabilization of p53 and cause cell cycle arrest.
Cells labeled for a prolonged period with 32P may therefore not
be growing when you harvest them.
Many years ago, Mike
Weber and Doc Edlin concluded that the specific activity
of the ATP pool had come to equilibrium with the phosphate in
the medium by 6 hours. There may therefore be no reason to label
for longer with 32Pi.
Overnight labeling is best done in medium
containing a reduced concentration of phosphate or methionine.
10% is often reasonable, depending on the cell line. This is
easily accomplished by using methionine-free or phosphate-free
medium and 10% undialyzed serum, which can be assumed to contain
the same concentration of methionine or phosphate as normal medium.
For short term labeling--30
seconds to 5 hrs--
use (1) medium completely lacking either phosphate or methionine,
(2) serum which has been dialyzed against saline, and
(3) a fairly low volume of medium;
0.75 ml for a 35 mm dish, 2 to 2.5 ml for a 50 mm dish, and 2.5
to 5 ml for a 100 mm dish.
It is a good idea to rinse the cells you are going to label with
labeling medium--which lacks label--prior to adding the actual
labeling medium. Starvation doesn't help much.
Back to